dc.contributor.author Roberts, H. M.
dc.contributor.author Wintle, A. G.
dc.date.accessioned 2013-07-13T04:04:38Z
dc.date.available 2013-07-13T04:04:38Z
dc.date.issued 2003-12
dc.identifier.citation Roberts , H M & Wintle , A G 2003 , ' Luminescence sensitivity changes of polymineral fine grains during IRSL and [post-IR] OSL measurements ' Radiation Measurements , vol 37 , no. 6 , pp. 661-671 . DOI: 10.1016/S1350-4487(03)00245-2 en
dc.identifier.issn 1350-4487
dc.identifier.other PURE: 519673
dc.identifier.other PURE UUID: d91181f5-ef02-40ff-b0a0-e0f13cf6a37c
dc.identifier.other WOS: 000186288700014
dc.identifier.other Scopus: 0043238043
dc.identifier.other handle.net: 2160/8935
dc.identifier.uri http://hdl.handle.net/2160/8935
dc.description Roberts, H. M., Wintle, A. G. (2003). Luminescence sensitivity changes of polymineral fine grains during IRSL and [post-IR] OSL measurements. Radiation Measurements, 37 (6), 661-671. en
dc.description.abstract Sensitivity changes during measurement sequences of infra-red-stimulated luminescence (IRSL) and post-IR optically stimulated luminescence (OSL) are presented for a sample of loess from northwestern China. Together with a dose recovery experiment, the results are used to investigate the ratio of 2.4 found for the D-e values (for IRSL and [post-IR] OSL) obtained when using a single-aliquot regenerative-dose (SAR) protocol in which both D-e values are obtained in a single sequence of measurements. Responses to test doses for both the IRSL and [post-IR] OSL show progressive luminescence sensitivity changes with repeated measurement cycles, with a slight dose dependence for the IRSL. In addition, five modified SAR procedures were used, varying preheats, filter combinations and method of measuring the luminescence signal. The D-e values for all IRSL measurements were at least 50% greater than those for the [post-IR] OSL signal. A modified SAR sequence was also applied in which 0.1 s stimulations (using both IR and blue light sources) were made between all sample treatments. A lack of consistency in the measured luminescence sensitivity of the natural IRSL signal suggests that the [post-IR] OSL signal provides the more reliable value of D-e. (C) 2003 Elsevier Ltd. All rights reserved. en
dc.format.extent 11 en
dc.language.iso eng
dc.relation.ispartof Radiation Measurements en
dc.rights en
dc.subject fine grain en
dc.subject IRSL en
dc.subject QUARTZ en
dc.subject GREEN LIGHT en
dc.subject luminescence en
dc.subject OSL en
dc.subject SINGLE-ALIQUOT en
dc.subject ACCUMULATION en
dc.subject SPECTRA en
dc.subject single-aliquot regenerative-dose (SAR) protocol en
dc.subject INFRARED STIMULATED LUMINESCENCE en
dc.subject ALKALI FELDSPARS en
dc.subject loess en
dc.subject CHINESE LOESS PLATEAU en
dc.subject PROTOCOL en
dc.title Luminescence sensitivity changes of polymineral fine grains during IRSL and [post-IR] OSL measurements en
dc.type /dk/atira/pure/researchoutput/researchoutputtypes/contributiontojournal/article en
dc.identifier.doi https://doi.org/10.1016/S1350-4487(03)00245-2
dc.contributor.institution Department of Geography and Earth Sciences en
dc.description.status Peer reviewed en


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search Cadair


Advanced Search

Browse

Statistics